Economizer Hoppers
| Economizer Hopper Ash Capture |
||
| Problem: | ![]() Photograph of Air Heater Flyash Fouling |
|
| A 600 MW coal-fired power plant was experiencing significant flyash fouling of the rotary air heater | ||
| Forced unit shutdown every 2-3 months for air heater cleaning | ||
| Estimated lost revenue of $50,000 per outage; air heater wash cost of $17,000 per wash | ||
| Total cost $67,000 per outage | ||
| |
||
![]() |
Solution: | |
| Using computer flow model, evaluate numerous design scenarios and operating conditions. | ||
| Determine final design that optimizes ash capture with minimum pressure loss and installation cost. | ||
| The final design captured 100% of ash particles greater than 500 microns in diameter. | ||
| |
||
![]() |
Results: | |
| After installation of recommended modifications, forced outages for air heater cleaning were eliminated. | ||
| Cost savings of $200,000 per year were realized by eliminating a minimum of 3 forced outages per year. | ||
| |
||